9.5 mm3/812.7mm1/219.0mm3/4TORQUE WRENCH, PRESET TYPE (DIGITAL READING)ModelsTorque Range(N・m)Incre-mentsUnitsSq.drA(mm)Dimensions (mm)Hand force at Max. torque(N)Suitable boltQty./CartonWeight(kg)Case DimensionsBHTLOrdinaryHigh strengthT3MN20H 4~200.2N・m9.524.021.410.4253110M6~M8M5~M610.30 355×97×75T3MN25H 5~250.2N・m9.524.021.410.4253138M6~M8M5~M610.30355×97×75T3MN50H10~500.5N・m9.536.026.314.0308227M10M810.52355×97×75T4MN50H10~500.5N・m12.736.030.014.0308227M10M810.55355×97×75T3MN100H20~1001N・m9.536.026.314.0387335M12~M14M1010.75 505×97×75T4MN100H20~1001N・m12.736.030.014.0387335M12~M14M1010.77 505×97×75T4MN140H30~1401N・m12.736.030.014.0450388M14M10~M1210.82 505×97×75T4MN200H40~2002N・m12.745.234.017.8526474M14~M16M1211.33 765×97×75T4MN300H40~3002N・m12.745.234.017.8716491M14~M20M12~M1411.84 765×97×75T6MN300H40~3002N・m19.045.240.517.8716491M14~M20M12~M1411.85 765×97×75Torque wrench with digital display for bolts/nuts tightening. Torque setting is available through the display that shows the numerical value. When the preset torque value is reached, the wrench will make a click sound and slight opposed force.When experience difficulty in removing socket bolt, socket exchange is possible with a simple push on the button.T4MN140HT3MN50HCAUTION●If the ball groove of sq.dr of socket or accessory is different from standard, holding mechanism often does not work. ●Strong shock often causes malfunction of holding mechanism. Digital display partVisible Indicator(Patent and design are already registered.)Socket holding mechanism※ Be sure to push the button when attaching or detaching.AccessoryCalibration Certicate W/H Traceability1Instruction Manual1Plastic Case1●Socket holding mechanism●N・m specication●Torque Accuracy± 3%The minimum capacity range of T4MN300H and T6MN300H has been expanded from 60N · m to 40N · m.※ This product is registered design.Calibration Certicate IncludedTest ReportTraceability Chart1.When not in use, the product can stay up to 3 years after calibration date mentioned in the certicate.2.If the usage started after 3 years from calibration date, it can be used up to 1 year since the rst usage or up to 10,000 tightening times.Expire Date of Calibration Certicate■Inaccuracy may occur if not used for a long time or impropriate use of tool. Please contact your distributor regularly for accuracy check.■Please contact your distributor in case of experiencing tool malfunction (no clicking sound, slight force, etc.)■Torque devices require regular inspection (once a year or 10,000 times afterwards). Checking service is available with service charge.■For more information about tool handling, please contact your distributor.■Accuracy range after repair will be ± 4%.Repair・Maintenance454
元のページ ../index.html#456